Vetter Mini-Lifting Bags 8.0 bar
Page 3/19
The built-in safety valve automatically activates when the bag is
over-inated above the maximum operating pressure of 8 bar or
when there is an unforeseen additional burden of the bag.
The activation tolerance for opening and closing of the
safety valve can be +/- 10 %.
Press the control lever in the opposite direction in order to deate
the bag or to reduce the load.
Additional information for illuminated control element
Air CU 8 bar deadman lighting
The lighting of the control element illuminates all couplings,
switch levers and manometers. It is switched on and o with
switch (1) on the side.
The control element is supplied by a 9 V block battery. Since the
entire lifting bag system is designed for a temperature range of
-20 °C to +55 °C, only batteries with this temperature range are
allowed to be used. Based on the current state of the art, only li-
thium batteries meet this requirement.
To insert the battery, unscrew the battery compartment, replace
the old battery with a new one and screw the battery compart-
ment back together.
Control elements with lighting come under the German Law on
electrical and electronic devices (ElektroG) of 24 March 2005 for
implementation of the EC Directive 2002/96/EC on electrical and
electronic waste – WEEE Directive.
The label attached to the battery compartment cover points
out that the electronic components in this product must not be
handled as domestic waste; they have to be returned to the ma-
nufacturer (return freight paid) for recycling.
d. Dual deadman controller 8 bar, aluminium
Press down the lower button (1) in order to inate the bag. Release
the button, thus ending the ination process, when the required
operating pressure for the lift power or lift height is reached. La-
test when the safety valve blows o or the red marking is reached!
Ination is stopped when the button is released and it returns
back to the zero position. The bag is released by pressing the up-
per button (2).
e. Single deadman controller 8 bar, aluminium
The single deadman controller can be used when only one Mini-
Lifting Bag is to be used.